-47- h hitron universal input harmonic correction ac-dc open frame single output 100 watts internal switching power supplies hvp103 series features: 5" x 3" x 1" compact size & high power density accommodate universal ac sources meet iec 61000-3-2 harmonic correction (pfc) meet universal safety standards emi meet en 55022 & fcc class b ce marking compliance for the details of safety approval, please consult the factory. specification input specification input voltage: typ. 90-264vac with pfc. input connector: v-m connector & gnd tag. input frequency: 47-63hz. inrush current: typ. 26a @ 230vac. input current: typ. 1.0a @115vac, 0.5a @230vac. dielectric withstand: meet iec 60950-1. emi: meet en 55022 & fcc class b. hold-up time: typ. 25ms @115vac & 230vac. power factor & harmonic correction: meet iec 61000-3-2, pf typ. 0.97-0.99 @ full load. turn-on delay/rise time: 2 sec./5ms. earth leakage: less than 0.5ma @230vac. output specification output voltage: see ratings chart. output current: see ratings chart. output power: 100w continuous. various with output voltage & under forced air cooling. output connector: v-m molex 0.156? connector for <12a output. m-t mini terminal block for 12a output. line regulation: typ. 0.1%. load regulation: typ. 1.0%. noise & ripple: typ. 1.0% peak to peak. ovp: built-in. adjustability: available. remote sensing: available. overload protection (olp): fully protected against output overload and short circuit. olp set at about 125-150% rating output wattage. consult the factory for olp setting. general specification efficiency: typ. 75-84%. various with output voltage. switching frequency: pwm 175k hz. (pfc: 75k hz.) circuit topology: fixed frequency forward circuit. transient response: 0.5ms following 25% load change. safety standard: iec 60950-1/ul 60950-1 class i. power density: 6.73 watts / cubic inch. operating temperature: 0 to +50c under 20 cfm forced air cooling for full load. storage temperature\humidity: -20 to +85c, 95% non-condensing. temperature coefficient: 0.04% /c. cooling: at least 20cfm moving air is required to achieve full rating power, +50c in a confined area. construction: l-bracket format. note: due to requests in market and advances in technol ogy, specifications subject to change without notification.
-48- output voltage / current ratings chart defined output voltage (vdc) ouput voltage (vdc) / current (a) 3.3vdc any voltage 12.0vdc 3.3-5.0vdc/ 20.0-18.0a, 5.1-6.0vdc/ 17.8-15.0a, 6.1-8.0vdc/ 14.8-11.0a, 8.1-10.0vdc/ 10.9-9.5a, 10.1-10.9vdc/ 9.4-9.0a, 11.0-12.0vdc/ 9.0-8.5a. 12.0vdc< any voltage 24.0vdc 12.1-14.0vdc/8.4-7.3a, 14.1-16.0vdc/7.3-6.4a, 16.1-18.0vdc/6.3-5.7a, 18.1-20.0vdc/5.6-5.1a, 20.1-22.0vdc/5.1-4.6a, 22.1-24.0vdc/4.6-4.2a single output (model no. for example) main o/p vo1 @# model no. min. typ. volt. peak continuous power hvp103-033200 0.8a 20.0a 3.3v 25.0a 66w hvp103-050180 0.6a 18.0a 5.0v 25.0a 90w hvp103-120085 0.0a 8.5a 12.0v 11.0a 102w hvp103-150068 0.5a 6.8a 15.0v 8.5a 103w HVP103-240042 0.3a 4.2a 24.0v 5.0a 100w symbol: " " ovp built-in. "@" adjustab le. "#" remote sensing. remark: peak output, less than 60sec. with 10% duty cycle. mechanical dimensions: mm [inches] weight: 319.0g (11.25 oz.) input & output connectors pin assignment ac input single output assignment line neutral ground vo1 dc-com remote sensing connector & pin # p1-1 p1-3 p1-5 p2-1,2( R 12a) p2-1,2,3(<12a) p2-3,4( R 12a) p2-4,5,6(<12a) p3-1(+s) p3-2(-s) mating connector: p1 & p2 molex # 5195 or 41695 equivalent. p3 molex # 5051 series or equivalent.
|